Illustration
Gallery
Description
Application
Steam accumulators are designed for equalising heat during variable heat load
Construction
Steam accumulators are made of structural carbon steel, as welded boiler drums.
Note
Design Pressure 1.0 MPa
Design Temperature 200oC
They are subject to UDT acceptance.
Dimension table
Steam accumulators– Ruth’s accumulators– vertical BZP | |||||||||||
Type | V | Dw | H | H1 | H2 | H3 | H4 | H5 | DN1 | DN2 | Weight |
m3 | mm | ~kg | |||||||||
BZP 1,0/800 | 1,0 | 800 | 2300 | 1790 | 840 | 400 | 370 | 400 | 25 | 20 | 345 |
BZP 1,5/1000 | 1,5 | 1000 | 2650 | 2080 | 880 | 420 | 370 | 500 | 25 | 20 | 585 |
BZP 2,0/1200 | 2,0 | 1200 | 2520 | 1900 | 950 | 450 | 390 | 400 | 32 | 25 | 695 |
BZP 2,5/1400 | 2,5 | 1400 | 2390 | 1780 | 1020 | 500 | 410 | 400 | 32 | 25 | 865 |
BZP 3,0/1400 | 3,0 | 1400 | 2980 | 2400 | 1100 | 550 | 500 | 500 | 50 | 32 | 1095 |
BZP 4,0/1600 | 4,0 | 1600 | 3000 | 2280 | 1080 | 550 | 420 | 500 | 50 | 32 | 1343 |
BZP 5,0/1800 | 5,0 | 1800 | 3100 | 2330 | 1130 | 550 | 420 | 500 | 50 | 32 | 1695 |