Design Pressure6/1.6 MPa Design Temperature 1000C / 2000C.
Illustration
Gallery
Description
Application
Capacity heat exchangers are designed for heating water for communal and industrial purposes. They may work at heating medium pressure 1,6 MPa and heated medium pressure 0,6 MPa and at tank temperature up to 1000C, coil pipe up to 2000C.
Construction
Capacity heat exchangers are made of structural carbon steel. The a/m exchangers are coated with anti-corrosion primer on the outside and with magnesium protector on the inside.
As a standard, heat exchangers are not equipped with thermal insulation.
Designation example
CAPACITY HEAT EXCHANGER, TYPE WP 6/16-9/I
Number 6 / 16 – represents max. pressure of heated/heating medium in bars.
Number 9 – represents number of the exchanger.
Number I – represents number of the coil pipe.
TABLE DIMENSIONS OF TERMAL EFFICIENCY
CALCULATION 1KW=860 KCAL/H
Type | Nominal capacity water tank
Vn |
The capacity of the heating system V`grz |
The diameter of the tank | Coil | Total Lenght L | Lenght Tank L1 |
Diameter heads
D1 |
Diameter tubes | Maximum efficiency of steam pressures and temperatures. | |||||
No coil | The capacity of the heating | Weight coil no protector | AA1 | BB1 | øE | O | ||||||||
16bar200°C | ||||||||||||||
dm3 | dm3 | mm | m2 | kg | mm | mm | mm | kW | ||||||
BWP-6/16-250/600/10 | 250 | 10 | 600 | I | 0,5 | 19,0 | 1293 | 1020 | 273 | 1 ¼” | 32 | 50 | ¾” | 81,4 |
BWP-6/16-250/600/11 | 11 | II | 0,7 | 22,0 | 114,0 | |||||||||
BWP-6/16-400/600/11 | 400 | 11 | 600 | I | 0,8 | 25,0 | 1943 | 1670 | 273 | 1 ¼” | 32 | 50 | ¾” | 130,2 |
BWP-6/16-400/600/13 | 13 | II | 1,2 | 29,0 | 195,4 | |||||||||
BWP-6/16-630/700/13 | 630 | 13 | 700 | I | 1,3 | 31,0 | 2248 | 1975 | 273 | 1 ¼” | 32 | 50 | ¾” | 215,7 |
BWP-6/16-630/700/16 | 16 | II | 2,2 | 43,0 | 358,2 | |||||||||
BWP-6/16-1000/900/42 | 1000 | 42 | 900 | I | 1,8 | 60,0 | 2323 | 1947 | 406 | 80 | 65 | 80 | 1 ½” | 293,0 |
BWP-6/16-1000/900/48 | 48 | II | 2,7 | 71,0 | 439,5 | |||||||||
BWP-6/16-1250/900/44 | 1250 | 44 | 900 | I | 2,2 | 67,0 | 2753 | 2377 | 406 | 80 | 65 | 80 | 1 ½” | 358,2 |
BWP-6/16-1250/900/49 | 49 | II | 3,3 | 86,0 | 537,3 | |||||||||
BWP-6/16-1500/1000/48 | 1500 | 48 | 1000 | I | 2,6 | 72,0 | 2650 | 2274 | 406 | 80 | 65 | 80 | 1 ½” | 423,3 |
BWP-6/16-1500/1000/51 | 51 | II | 4,7 | 100,0 | 765,2 | |||||||||
BWP-6/16-2000/1250/49 | 2000 | 49 | 1250 | I | 3,36 | 83,0 | 2400 | 2188 | 406 | 80 | 65 | 80 | 1 ½” | 546,6 |
BWP-6/16-2000/1250/52 | 52 | II | 6,76 | 114,0 | 936,2 | |||||||||
BWP-6/16-2500/1250/51 | 2500 | 51 | 1250 | I | 4,3 | 94,0 | 2800 | 2834 | 406 | 80 | 65 | 80 | 1 ½” | 700,1 |
BWP-6/16-2500/1250/53 | 53 | II | 7,1 | 133,0 | 1156,0 | |||||||||
BWP-6/16-3150/1250/67 | 3150 | 67 | 1250 | I | 5,5 | 110,0 | 3365 | 2990 | 406 | 80 | 65 | 80 | 1 ½” | 895,5 |
BWP-6/16-3150/1250/71 | 71 | II | 9,0 | 159,0 | 1465,0 | |||||||||
BWP-6/16-4000/1250/64 | 4000 | 64 | 1250 | I | 7,2 | 134,0 | 4065 | 3690 | 406 | 80 | 65 | 80 | 1 ½” | 1180,0 |
BWP-6/16-4000/1250/80 | 80 | II | 11,2 | 192,0 | 1826,0 |