BEPIS Offer Steel tanks Heat exchanger Capacity heat exchanger, type BWP 6/6

Capacity heat exchanger, type BWP 6/6

Illustration

Gallery

Description

Application

Capacity heat exchangers are designed for heating water for communal and industrial purposes. They may work at heating medium pressure 0,6 MPa and heated medium pressure 0,6 MPa, and at tank temperature up to  1000 C, coil pipe up to  2000 C.

Construction

Capacity heat exchangers are made of structural carbon steel. The a/m exchangers are coated with anti-corrosion primer on the outside and with magnesium protector on the inside.

As a standard, heat exchangers are not equipped with thermal insulation.

Designation example

CAPACITY HEAT EXCHANGER, TYPE WP 6/6-9/I

Number 6 / 6 – represents max. pressure of heated/heating medium in bars.

Number 9 – represents number of the exchanger.

Number I – represents number of the coil pipe.

TABLE DIMENSIONS OF TERMAL EFFICIENCY
CALCULATION 1KW=860 KCAL/H

Type Capacity min water tank    Vn Capacity heating system

V`grz

Diameter tank

Dw

Coil Lenght total

L

Lenght tank L1 Diameter heads D1 Diameter tubes Intial Temp.  wather Two= +50C Weight
No coil Heaiting surfaces Weight coil without protector AA1 BB1 øE O
 
 The vapor pressure and temperature.
The parameters of heating water
0,5bar110,8°C 3bar142,9°C 6bar164,2°C 90/70 130/70 150/70
dm3 D mm  – m2 kg mm mm mm kW kW kW kW kW kW ~kg
BWP-6/6- 250/600/10 250 10 600 I 0,5 19 1293 1020 273 1 ¼” 1 ¼” 40 ¾” 38,2 53,1 62,9 12,8 15,1 16,3 133
BWP-6/6- 250/600/11 11 II 0,7 22 53,6 74,4 88,0 17,4 19,8 20,9 138
BWP-6/6- 400/600/11 400 11 600 I 0,8 25 1943 1670 273 1 ¼” 1 ¼” 40 ¾” 61,3 85,0 100,6 22,1 29,1 31,4 192
BWP-6/6- 400/600/13 13 II 1,2 29 91,9 127,6 150,8 33,7 43,0 47,7 197
BWP-6/6- 630/700/13 630 13 700 I 1,3 31 2248 1975 273 1 ¼” 1 ¼” 40 ¾” 91,9 127,6 150,8 33,7 73,0 47,7 292
BWP-6/6- 630/700/16 16 II 2,2 43 166,9 231,8 274,1 61,6 80,2 87,2 304
BWP-6/6- 1000/900/42 1000 42 900 I 1,8 60 2323 1947 406 80 65 50 1 ½” 137,8 191,3 226,3 51,2 66,3 73,3 379
BWP-6/6- 1000/900/48 48 II 2,7 71 206,6 287,0 339,5 76,8 100,0 110,5 391
BWP-6/6- 1250/900/44 1250 44 900 I 2,2 67 2753 2377 406 80 65 50 1 ½” 168,4 233,9 276,6 64,0 84,9 95,4 427
BWP-6/6- 1250/900/49 49 II 3,3 86 252,6 350,9 415,0 96,5 127,9 141,9 446
BWP-6/6- 1500/1000/48 1500 48 1000 I 2,6 72 2650 2274 406 80 65 50 1 ½” 199,1 276,4 326,9 75,6 100,0 110,5 454
BWP-6/6- 1500/1000/51 51 II 4,7 100 359,8 499,7 590,9 137,2 181,4 200,0 492
BWP-6/6- 2000/1250/49 2000 49 1250 I 3,36 83 2400 2188 406 80 65 50 1 ½” 257,2 357,3 422,4 96,5 126,8 140,7 622
BWP-6/6- 2000/1250/52 52 II 6,76 114 440,2 611,3 722,9 166,3 217,5 239,6 654
BWP-6/6- 2500/1250/51 2500 51 1250 I 4,3 94 2800 2834 406 80 65 50 1 ½” 329,2 457,2 540,7 127,9 171,0 190,7 719
BWP-6/6- 2500/1250/62 62 II 7,1 133 543,6 754,9 892,7 211,7 283,8 315,2 757
BWP-6/6- 3150/1250/57 3150 57 1250 I 5,5 110 3365 2990 406 80 65 50 1 ½” 421,1 584,8 691,5 167,5 229,1 255,9 855
BWP-6/6- 3150/1250/71 71 II 9,0 159 689,1 956,8 1131,6 274,5 374,5 418,7 904
BWP-6/6- 4000/1250/64 4000 64 1250 I 7,2 134 4065 3690 406 80 65 50 1 ½” 551,7 765,5 905,3 222,1 305,9 343,1 672
BWP-6/6- 4000/1250/80 80 II 11,2 192 857,5 1190,8 1408,2 345,4 475,7 533,8

1030