BEPIS Offer Blacksmith products for water and sewer installations and heating installations Support pillars type „A” for heaters
Illustration
Gallery
Description
Application
Support pillars are designed for storage heaters type PP No 4-11, of capacity 800 4000 m3 installed in rooms, where application of stays is impossible.
Order example
Note
Support pillars painted with primer.
Dimension table
Heater | L | L1 | L2 | a | Beam | Column | Construction height and weight in kilograms | |||||
Number | Capacity | Dz | mm | mm | mm | mm | IPE | H=1250 | H=1500 | H=1750 | H=2000 | |
4 | 800 | 810 | 1085 | 900 | 1200 | 280 | 80 | 80 | 48,0 | 52,0 | 53,5 | 59,5 |
5 | 1000 | 910 | 1155 | 970 | 900 | 300 | 80 | 80 | 45,0 | 50,0 | 54,0 | 58,0 |
6 | 1250 | 910 | 1155 | 970 | 1170 | 300 | 80 | 80 | 48,5 | 525,0 | 56,5 | 60,0 |
7 | 1500 | 1012 | 1266 | 1030 | 1170 | 310 | 80 | 80 | 50,0 | 53,0 | 58,0 | 62,0 |
8 | 2000 | 1212 | 1400 | 1170 | 900 | 344 | 100 | 80 | 64,0 | 69,0 | 74,0 | 77,5 |
9 | 2500 | 1212 | 1400 | 1170 | 1400 | 344 | 100 | 100 | 78,0 | 83,5 | 83,0 | 95,0 |
10 | 3250 | 1212 | 1400 | 1170 | 1850 | 344 | 120 | 100 | 92,0 | 97,0 | 102,0 | 107,5 |
11 | 4000 | 1212 | 1400 | 1170 | 2600 | 344 | 140 | 120 | 138,0 | 144,0 | 151,0 | 158,0 |